suite id g_two_hand_fb
domain manufacturing
language LD-graphical
difficulty medium
validation status candidate
origin authored
license CC-BY-4.0
syntax pair of g_two_hand

The ISO 13851 Type II logic of g_two_hand moved into a reusable function block, the shape certified safety libraries ship it in

What is proved

From benchmarks/manufacturing/g_two_hand_fb/props.yaml. What each kind claims, and what it becomes on either route, is on The properties we prove.

id kind claim requirement
P1 invariant !Stroke || (LH && RH) ISO 13851 requires the ram to descend only while both actuators are held. Releasing either one stops the stroke.

Variants

file expected verdict violates method
program.xml SAFE none expert
type_i.xml SAFE none fault-injection

Files

file what it is size sha256
benchmark.yml benchmark metadata 1.4 KB df2981b0eff8
program.xml ladder program, PLCopen XML 3.7 KB d2d99912ea21
props.yaml property file 0.2 KB 01c905820f28
tiedown_check.props.yaml property file 0.5 KB d1118ab8f733
type_i.xml ladder program, PLCopen XML 3.6 KB fda94b735538

Structured text, derived

Read off the ladder graph by runner/ld_to_st.py: every rung's contacts and coils rewritten as IEC 61131-3 assignments, in the same series/parallel logic the PLCopen XML encodes. This is a reading aid, not a second source of expected verdicts; ESBMC verifies the ladder program shown above, never this rendering.

PROGRAM g_two_hand_fb
VAR_INPUT
    LH : BOOL;
    RH : BOOL;
END_VAR

VAR_OUTPUT
    Stroke : BOOL;
END_VAR

VAR
    THC0 : TwoHandII;
END_VAR


THC0(EN:=TRUE, LH:=LH, RH:=RH);
Stroke := THC0.Stroke;

END_PROGRAM
PROGRAM g_two_hand_fb_type_i
VAR_INPUT
    LH : BOOL;
    RH : BOOL;
END_VAR

VAR_OUTPUT
    Stroke : BOOL;
END_VAR

VAR
    THC0 : TwoHandII;
END_VAR


THC0(EN:=TRUE, LH:=LH, RH:=RH);
Stroke := THC0.Stroke;

END_PROGRAM

Recorded runs

A task can carry two routes. ld is ESBMC's ladder front end reading the program directly. via C is the same solver reached through Beremiz and MatIEC, which is the only route that reaches ST, IL, FBD and SFC; see How ESBMC-PLC works.

  • g_two_hand_fb__program (props.yaml, expected SAFE): v8.4 SAFE — ingestion gate failed on v8.4
  • g_two_hand_fb__type_i (props.yaml, expected SAFE): v8.4 VIOLATION
  • twohand_fb_tiedown_i (tiedown_check.props.yaml, expected SAFE): master VIOLATION
  • twohand_fb_tiedown_ii (tiedown_check.props.yaml, expected VIOLATION): master VIOLATION — ingestion gate failed on master